AUTOMATED MEASURING SYSTEM BASED ON GTEM-CAMERA

AUTOMATED MEASURING SYSTEM BASED ON GTEM-CHAMBER

GTEM

GTEM-camera is designed for the measurement of side alectromagnetic radiation of different products in wide frequency range (9 kHz to 1 GHz and higher) under condirions simulating free space and providing protection from impact of external electromagnetic fields, which is virtually impossible to provide on test sites or anechoic chambers of other types.

Technical specifications GTEM-camera:

  • operating range of GTEM-camera fron 0,009 to 1,000 MHz (expandable);
  • shielding effectiveness GTEM-camera, dB - 60;
  • stading wave ratio Ku - 1.2;
  • wave resistance, Ohms - 50;
  • working area GTEM-camera, m - 1.2x1.2x1.0;
  • overall dimensions, m 8.0x4.0x3.0;
  • weight of GTEM-camera, kg - not more than 1940.

Complex structure:

  • GTEM-camera;
  • radar-absorbing material;
  • spectrum analyzer ("Rohde & Schwarz" or "Agilent Technologies");
  • managing personal computer;
  • monitor of CCTV system;
  • video camera;
  • rotating platform;
  • remote control of rotating platform;
  • filter unit;
  • scanning resceiver;
  • source of the acoustic test signal.